Performance Monitoring
Measurement Properties
162 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Command Example:
RTRV-PM::CLK-4:SC1::TIE;
The response to the command in this example displays TIE information about input
port 4.
Response Example:
SYMMBITS 04-06-15 12:07:38
M SC1 COMPLD
"CLK1-4:TIE-1S,2.000000,COMPL"
"CLK1-4:TIE-1M,2.000000,COMPL"
"CLK1-4:TIE-15M,2.000000,COMPL"
"CLK1-4:TIE-30M,2.000000,COMPL"
"CLK1-4:TIE-1H,2.000000,COMPL"
"CLK1-4:TIE-2H,NA,NA"
"CLK1-4:TIE-8H,NA,NA"
"CLK1-4:TIE-24H,NA,NA"
;
The response in this example shows TIE values for observation time intervals of
1 second, 1 minute, 15 minutes, 30 minutes, and 1 hour for input port 4 of Clock
card 1. The values for time intervals of 2 hours, 8 hours, and 24 hours are not yet
available, but do become available as the system collects data.
Measurement Properties
Measurement property descriptions and factory settings are listed in Table 4-7.
TIE-15M 15 min 15 min 15 min
TIE-30M 30 min 15 min 30 min
TIE-1H 1 h 15 min 1 h
TIE-2H 2 h 15 min 2 h
TIE-8H 8 h 15 min 8 h
TIE-24H 24 h 15 min 24 h
Table 4-6 TIE Measurements and Time Periods for Single Input Port (Continued)
Measurement
Observation Time
First Data
Available After
Updated Every
Includes Data
from Last

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals