Performance Monitoring
Measurement Properties
162 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Command Example:
RTRV-PM::CLK-4:SC1::TIE;
The response to the command in this example displays TIE information about input
port 4.
Response Example:
SYMMBITS 04-06-15 12:07:38
M SC1 COMPLD
"CLK1-4:TIE-1S,2.000000,COMPL"
"CLK1-4:TIE-1M,2.000000,COMPL"
"CLK1-4:TIE-15M,2.000000,COMPL"
"CLK1-4:TIE-30M,2.000000,COMPL"
"CLK1-4:TIE-1H,2.000000,COMPL"
"CLK1-4:TIE-2H,NA,NA"
"CLK1-4:TIE-8H,NA,NA"
"CLK1-4:TIE-24H,NA,NA"
;
The response in this example shows TIE values for observation time intervals of
1 second, 1 minute, 15 minutes, 30 minutes, and 1 hour for input port 4 of Clock
card 1. The values for time intervals of 2 hours, 8 hours, and 24 hours are not yet
available, but do become available as the system collects data.
Measurement Properties
Measurement property descriptions and factory settings are listed in Table 4-7.
TIE-15M 15 min 15 min 15 min
TIE-30M 30 min 15 min 30 min
TIE-1H 1 h 15 min 1 h
TIE-2H 2 h 15 min 2 h
TIE-8H 8 h 15 min 8 h
TIE-24H 24 h 15 min 24 h
Table 4-6 TIE Measurements and Time Periods for Single Input Port (Continued)
Measurement
Observation Time
First Data
Available After
Updated Every
Includes Data
from Last