Commands
Command Description
72 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
The command in this example displays MRTIE information about input channel 4.
Response Example:
SYMMBITS 98-09-05 12:07:38
M SC1 COMPLD
"CLK1-4:MRTIE-1S,2.000000,COMPL,,,75-MIN"
"CLK1-4:MRTIE-1M,2.000000,COMPL,,,75-MIN"
"CLK1-4:MRTIE-15M,2.000000,COMPL,,,75-MIN"
"CLK1-4:MRTIE-30M,2.000000,COMPL,,,75-MIN"
"CLK1-4:MRTIE-1H,2.000000,COMPL,,,75-MIN"
"CLK1-4:MRTIE-2H,NA,NA,,,75-MIN"
"CLK1-4:MRTIE-8H,NA,NA,,,75-MIN"
"CLK1-4:MRTIE-24H,NA,NA,,,75-MIN"
;
The response in this example indicates that MRTIE data was collected over the past
75 minutes (measurement time) and MRTIE values have been calculated for
observation times of 1 second, 1 minute, 15 minutes, 30 minutes, and 1 hour. The
values for observation times of 2 hours, 8 hours, and 24 hours are not yet available
because the system has not been running long enough to collect that data. These
values become available as the unit continues to collect data. The total
measurement time is only indicated for MRTIE measurements and continues to
increase in 15 minute increments for 24 hours. The <aid> field indicates that this
data was collected by Clock card 1.
Once the measurement time reaches 24 hours, data prior to 24 hours is lost as new
data is collected. A specific measurement can be specified if only that one value is
desired (for example,
RTRV-PM::CLK-4:SC1::MRTIE-1S;).
Retrieve Port Security
This command displays the state of a communication port. The command format is:
RTRV-CID-SECU:[<tid>]:<aid>:<ctag>;
Command Example:
RTRV-CID-SECU::LOCAL:SC1;
The command in this example displays the state of the local port.
Parameter Value Description
<aid> REMOTE Communication port
LOCAL