097-55501-02 Issue 7 – January, 2005 TimeHub 5500 TL1 Reference Guide 143
Keywords
Keyword Description
Command Example:
RTRV-SYNC::CLK-2:SC1745:::PARAMETER=TCONSTSEC;
Response Example:
SYMMBITS 04-06-18 12:06:40
M SC1745 COMPLD
"CLK-2::TCONSTSEC = 384"
;
TIDQUIET (TID Quiet)
This keyword causes the system to suppress the DENY response that is normally
generated when the target identifier <tid> specified in the current command does
not match the current system identifier <sid>. The keyword format is:
TIDQUIET=<value>
TRAFFIC (Traffic Data Pattern)
This keyword specifies a data pattern to be carried in the traffic time slots of the
Output Driver card.
The keyword format is:
TRAFFIC=<value>
Parameter Value Description
<value> Y DENY response is not displayed when the <tid>
specified is not the same as the current <sid>
N DENY response is displayed when the <tid> specified
is not the same as the current <sid>
Note: 255 (all ones) is the preferred value because this causes the
greatest number of clock pulses to occur.

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals