Performance Monitoring
Measurement Properties
164 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Response Format:
<sid> <date> <time>
M <ctag> COMPLD
"<aid>::<montype>=THR-a&CRI-a&RPT-a&PM-a&GOOD-a:"
;
The parameters displayed in the response are listed below.
<montype> FFOFF-a a = 3S, 12S, 48S,
192S, 768S, 3072S
FFOFF monitored type, where a is the averaging
time interval in seconds
LMRTIE-a a = 1S, 1M, 15M, 30M,
1H, 2H, 8H, 24H
LMRTIE monitored type, where a is the
observation time interval in seconds (S), minutes
(M), or hours (H)
MRTIE-a a = 1S, 1M, 15M, 30M,
1H, 2H, 8H, 24H
MRTIE monitored type, where a is the
observation time interval in seconds (S), minutes
(M), or hours (H)
SPRD-a a = 3S, 12S, 48S,
192S, 768S, 3072S
SPRD monitored type, where a is the averaging
time interval in seconds
TDEV-a a = 1S, 4S, 16S, 64S,
256S, 1024S
TDEV monitored type, where a is the averaging
time interval in seconds
TIE-a a = 1S, 1M, 15M, 30M,
1H, 2H, 8H, 24H
TIE monitored type, where a is the observation
time interval in seconds (S), minutes (M), or
hours (H)
Parameter Value Variables Description
<aid> CLK-a a = 1 to 4 Input port number of Clock card. Applies to
monitored types other than SPRD.
CLK All ports of Clock card. Applies to SPRD
monitored type only.
Parameter Value Variables Description

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals