Performance Monitoring
Measurement Properties
164 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
Response Format:
<sid> <date> <time>
M <ctag> COMPLD
"<aid>::<montype>=THR-a&CRI-a&RPT-a&PM-a&GOOD-a:"
;
The parameters displayed in the response are listed below.
<montype> FFOFF-a a = 3S, 12S, 48S,
192S, 768S, 3072S
FFOFF monitored type, where a is the averaging
time interval in seconds
LMRTIE-a a = 1S, 1M, 15M, 30M,
1H, 2H, 8H, 24H
LMRTIE monitored type, where a is the
observation time interval in seconds (S), minutes
(M), or hours (H)
MRTIE-a a = 1S, 1M, 15M, 30M,
1H, 2H, 8H, 24H
MRTIE monitored type, where a is the
observation time interval in seconds (S), minutes
(M), or hours (H)
SPRD-a a = 3S, 12S, 48S,
192S, 768S, 3072S
SPRD monitored type, where a is the averaging
time interval in seconds
TDEV-a a = 1S, 4S, 16S, 64S,
256S, 1024S
TDEV monitored type, where a is the averaging
time interval in seconds
TIE-a a = 1S, 1M, 15M, 30M,
1H, 2H, 8H, 24H
TIE monitored type, where a is the observation
time interval in seconds (S), minutes (M), or
hours (H)
Parameter Value Variables Description
<aid> CLK-a a = 1 to 4 Input port number of Clock card. Applies to
monitored types other than SPRD.
CLK — All ports of Clock card. Applies to SPRD
monitored type only.
Parameter Value Variables Description