Commands
Command Description
48 TimeHub 5500 TL1 Reference Guide 097-55501-02 Issue 7 – January, 2005
ED-SYNC[-TSG]:[<tid>]:<aid>:<ctag>:::<measurement>=<value>;
<keyword> AUTOPM — Auto-Upload PM
B8ZS B8ZS
CCDENB CC Delay
ENABLE Input Enable
ESF ESF
MEASDLY Measurement Delay
MONITOR Input Event Monitoring
PRC5MHZ PRC 5MHz Signal
PRIORITY Input Priority
QCUTOFF Quality Cutoff
SQUELCH Squelch Output
SSMENB Read SSM Bits
SSMPRI SSM Priority Grouping
TCONST Time Constant
TCONSTSEC Time Constant for Secondary Oscillator
<value> See Chapter 3, Keywords.
Parameter Value Variables Description
<aid> CLK-a a = 0 – 4
(5- and 9-input
clocks)
0 = PRS (5 or 10 MHz)
1 – 4 = DS1 terminated inputs
5 – 8 = DS1 bridged inputs
10 = CC 1 input
11 = CC 2 input
a = 5 – 8
(9-input clocks
only)
a = 10 – 11
(remote shelf)
Sa-OUTb-c a = 0 – 4 Shelf number (0 is main shelf). This prefix
is optional for main shelf.
Parameter Value Variables Description