1.2.6.4.1 Safety specifications
1.2.6.4.1.1 System requirements
Required Firmware
v4.2.0 or higher
Supported Hardware
SOMANET Circulo 7
SOMANET Circulo 9
1.2.6.4.1.2 Technical specifications
Safety parameters
Safety Integration level (SIL) according to IEC
61508:2010
SIL 3
Performance Level (PL) according to ISO 13849-
1:2015
PL e cat. 3
Safe Failure Fraction (SFF) TBD
Probability of dangerous failure per hour (PFH ) TBD
Probability of dangerous failure on demand (PFD ) TBD
Common Cause Failure (CCF) TBD
Hardware Fault Tolerance (HFT) 1
Reaction time 10 ms
De-activation time 10 ms
Mean Time to dangerous Failure (MTTF ) TBD
Diagnostic coverage (DC ) TBD
HW-type Type A
Mission time T TBD
Supported safety modes High, Low
Installation requirements
Max. installation altitude 2000 m
d
avg
d
avg
M
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 201/887

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYNAPTICON CIRCULO 7 and is the answer not in the manual?

SYNAPTICON CIRCULO 7 Specifications

General IconGeneral
BrandSYNAPTICON
ModelCIRCULO 7
CategoryServo Drives
LanguageEnglish

Related product manuals