EasyManuals Logo

SYNAPTICON CIRCULO 7 User Manual

SYNAPTICON CIRCULO 7
887 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #618 background imageLoading...
Page #618 background image
3.1.9.1.43 0x2005 Recuperation
Configuration parameter for recuperation
Name Index:Sub Type Bit
Size
Options Unit Access PDO
Mapping
Recuperation
enabled
0x2005:1 BOOL 1
Disabled 0
Enabled 1
readwrite
Enables or disables the recuperation feature.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Min battery
energy
0x2005:2 UINT 16 0 V readwrite
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Max battery
energy
0x2005:3 UINT 16 0 V readwrite
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Min recuperation
power
0x2005:4 UINT 16 0 W readwrite
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Max
recuperation
power
0x2005:5 UINT 16 0 W readwrite
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Minimum
recuperation
speed
0x2005:6 UINT 16 0 rpm readwrite
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Maximum
recuperation
speed
0x2005:7 UINT 16 0 rpm readwrite
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 618/887

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYNAPTICON CIRCULO 7 and is the answer not in the manual?

SYNAPTICON CIRCULO 7 Specifications

General IconGeneral
BrandSYNAPTICON
ModelCIRCULO 7
CategoryServo Drives
LanguageEnglish

Related product manuals