3.1.9.1.143 0x6085 Quick stop deceleration
Indicates the deceleration used to stop the motor when the quick stop function is activated. The units are in
RPM per second.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Quick stop
deceleration
0x6085:0 UDINT 32 1 10000 rpm/s readwrite Receive
PDO
(Outputs)