3.1.9.1.114 0x6062 Position demand value
Provides the value of the position sent to the position controller after position limits are checked. See 0x607D
Software position limit. The units are in increments of the position encoder.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Position demand
value
0x6062:0 DINT 32 0 Inc readonly
(default)