3.1.9.1.119 0x6068 Position window time
Configures the time required for the position sensor to be within the position window before it's considered to
be within the window. The units are in milliseconds.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Position window
time
0x6068:0 UINT 16 0 ms readwrite Receive
PDO
(Outputs)
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 762/887