4.1.1.1.2 What the Servo Drive has to Provide
AC Power: P = I U
U
I is limited by the Servo Drive by the Motor Note
in continuous
rated
operation
Continuous current Continuous current Thermal limit on any component that has
to carry current. (FETs and motor windings)
in continuous
stall operation
Continuous current Continuous stall
current
Similar thermal limit as in continuous rated
operation.
Since there are no iron losses here, the
motor can stand a bit more.
in max
intermittent
operation
Max intermittent
current
Max intermittent
current
Max current can be applied for a short time
only (e.g. 250 ms).
Exceeding it would immediately burn the
windings.
AC RMS RMS
RMS voltage
RMS
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 832/887