4.1.6.2.4 General structure of the Controlword
1515
1414
1313
1212
1111
1010
99
88
77
66
55
44
33
22
11
00
ms
ms
ms
ms
ms
r
oms
h
fr
oms
oms
oms
eo
qs
ev
so
N/A
basic
operation mode specific bits
basic
Note
bits 9,10,11,12,13,14 and 15 are not used.
Legend:
Abbr. Meaning
so switched on
ev enable voltage
qs quick stop
eo enable operation
oms operation mode specific
fr fault reset
h halt
oms operation mode specific
r reserved
ms manufacturer specific
State Coding
CommandCommand
b7b7
b3b3
b2b2
b1b1
b0b0
TransitionsTransitions
Shutdown
0
x
1
1
0
2,6,8
Switch on
0
0
1
1
1
3
Switch on + enable operation
0
1
1
1
1
3+4 (NOTE)
Disable voltage
0
x
x
0
x
7,9,10,12
quick stop
0
x
0
1
x
7,10,11
disable operation
0
0
1
1
1
5
enable operation
0
1
1
1
1
4,16
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 854/887

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYNAPTICON CIRCULO 7 and is the answer not in the manual?

SYNAPTICON CIRCULO 7 Specifications

General IconGeneral
BrandSYNAPTICON
ModelCIRCULO 7
CategoryServo Drives
LanguageEnglish

Related product manuals