3.1.9.1.66 0x20F0 Timestamp
Position signal measurement timestamp. Unsigned 32bit integer, resets after 42,949,672 ((2^32 - 1) / 100) µs.
Name Index:Sub Type Bit
Size
Min
Data
Max Data Default
Data
Unit Access PDO
Mapping
Timestamp 0x20F0:0 UDINT 32 0 4294967295 0 μs readonly