3.1.9.1.123 0x606E Velocity window time
Configures the time the velocity controller needs to be within the velocity window to consider it having
reached the target. The units are in milliseconds.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Velocity window
time
0x606E:0 UINT 16 0 ms readwrite Receive
PDO
(Outputs)
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 766/887