TmpDrive This fault is triggered when
the temperature of the
drive becomes too high
and crosses the error
threshold (> 100 °C). This
happens usually because
of sustained load on the
processor, current leakage
from the on-board
componenets, high
operating frequency and
even ambient
temperature. High drive
temperature can lead to
equipment damage.
Disable the drive until the reason for the
error is resolved or use external cooling to
bring down the over-all temperature.