2.2 Mechanical Installation
50 YASKAWA ELECTRIC SIEP C710616 35D YASKAWA AC Drive E1000 Technical Manual
■ IP20/NEMA 1, UL Type 1 Enclosure Drives
Note: IP20/NEMA 1, UL Type 1 enclosure drives are equipped with a top cover. Removing this cover voids IP20/NEMA 1, UL Type 1
protection but still keeps IP20 conformity.
Table 2.4 Dimensions for IP20/NEMA 1, UL Type 1 Enclosure: 200 V Class
Drive Model
CIMR-E2A
Dimensions (mm)
Figure W H D W1 H0 H1 H2 H3 D1 t1 t2 d
Weight
(kg)
0004
1
<1>
140 260 147 122 – 248 6 – 38 5 – M5 3.1
0006 140 260 147 122 – 248 6 – 38 5 – M5 3.1
0008 140 260 147 122 – 248 6 – 38 5 – M5 3.2
0010 140 260 147 122 – 248 6 – 38 5 – M5 3.2
0012 140 260 147 122 – 248 6 – 38 5 – M5 3.2
0018 140 260 164 122 – 248 6 – 55 5 – M5 3.5
0021 140 260 164 122 – 248 6 – 55 5 – M5 3.5
0030 140 260 167 122 – 248 6 – 55 5 – M5 4.0
0040 140 260 167 122 – 248 6 – 55 5 – M5 4.0
0056 180 300 187 160 – 284 8 – 75 5 – M5 5.6
0069 220 350 197 192 – 335 8 – 78 5 – M6 8.7
0081
2
<1>
220 365 197 192 350 335 8 15 78 5 – M6 9.7
W1
4-d
H1
H
H0
H2
H3
W
Max.8 Max.8
D
D1
t2
t1
Figure 3
H2
W1
1.5
H
H0
H1
W
D1
D
t1
H3
Figure 2
4-d
W1
1.5
H
H1
H2
W
D
D1
t1
Figure 1
4-d
SIEP_C710616_35.book 50 ページ 2015年11月30日 月曜日 午後2時2分