System Setup
9 - 186
9.16 Changing output status
The status of general purpose output signals can be changed from the programming
pendant by using either of the following two methods.
• On the general purpose output status window
• On the RELAY ON window
The method that uses the RELAY ON window, which is described here, simplifies the
operation for changing the status of signals that are used frequently.
NOTICE
A maximum of 64 general purpose output signals can be shown on the RELAY ON window
and they must be set in advance to parameters S4C327 to S4C390. If they are not set, the
sub menu in the RELAY ON window will not be displayed.
1. Select {IN/OUT} under main menu.
2. Select {RELAY ON}.
– The RELAY ON window appears.
3. Select the desired signal to change the output status.
– Select the status ( or ) of the desired signal.
4. Press [INTERLOCK] +[SELECT].
– The output status is changed (: status ON; : status OFF).
NOTICE
It is also possible to turn the relevant general purpose output signal on only for the duration
that the interlock key + [SELECT] are pressed. This selection is made in advance by setting
the parameters (S4C391 to 454) to “1”.