System Setup
9 - 290
9.26.16 Saving or loading the file
9.26.16.1 Saving the file
The safety logic circuit file can be saved into the SD card/USB memory stick of the
programming pendant or the USB memory stick of the CPU board. Make sure the medium
is inserted into the device of the save destination. Perform the following operations.
1. Displaying the window.
Select {I/O DATA}, by going to {SAVE} from {EX. MEMORY} in the main menu.
The signal list relative to the I/O data is displayed, and then select “YSF LOGIC FILE”.
2. The confirmation dialog appears, and select “YES”.
3. The safety logic circuit file (File name:YSFLOGIC.DAT) is saved in the specified device
9.26.16.2 Loading the file
The safety logic circuit file can be loaded from the SD card/USB memory stick of the
programming pendant or the USB memory stick of the CPU board. Make sure the medium
is inserted into the device of the load destination. Perform the following operations.
1. Displaying the window.
Select {I/O DATA}, by going to {LOAD} from {EX. MEMORY} in the main menu.
The signal list relative to the I/O data is displayed, and then select “YSF LOGIC FILE”.
2. The confirmation dialog appears, and select “YES”.
3. The safety logic circuit file (File name:YSFLOGIC.DAT) is loaded from the specified
device.