System Setup
9 - 326
9.30.1.2 Display of user group input
1. Select {I/O} in the main menu.
2. Select {USER GROUP INPUT}.
The USER GROUP INPUT window is shown.
NOTICE
All the general purpose input signals which belong to the group in the status of “SIM” are in
the status of “SIM” (For details of this status, refer to “OPTIONS INSTRUCTIONS FOR
Concurrent I/O (Document-No.: E1102000222XX01 or higher) in chapter „Changing Signal
Status from General Purpose Input Status Window“).
SIM: Manual operation is possible
(Blank): Normal status
9.30.2 User group output
9.30.2.1 User group output setting
Set the security to the MANAGEMENT mode.
1. Select {I/O} in the main menu.
2. Select {USER GROUP OUTPUT}.
The USER GROUP OUTPUT window is shown.
SIM
Normally, the input status of the user group cannot be changed by manual operation.
However, the status can be set to be changeable for the operation check and etc. The
status is changed every time an item is selected.
VALUE
The input status of the user group.
When the group in the “SIM” status is selected, the value can be changed.
PARITY
Specify the parity check.**: No parity check
: 0
: 1
NAME
The group signal name is set.
1
2
3
4

Table of Contents