System Setup
9 - 218
• Invalidate the warning output signal
Able to invalidate for each axis. Invalidate the warning output signal by the following
procedures, in case of the speed reducer seems to operate normally even though the
warning output signal is turned ON.
1. Select {=PM} in the main menu.
– The sub menu appears.
2. Select {=PM(REDUCER)}.
– The lifetime calculation window appears.
3. Select {Display}.
– The pull down menu appears.
4. Select {=TORQUE MONITOR}.
– The torque monitor window appears.
Move the cursor over the “=WARNING” of the desired axis to invalidate, and press [Select].
[Invalid] and [Valid] will alternate each time when press the [Select].
• Graph display
After the measurement, the variation can be checked by a graph.
The graph is updated every 24 hours automatically. The measured value and changes
of the variation can be displayed on the programming pendant. Thus, the changes of
the torque can be checked visually.
Use the graph display as the one of the methods to judge the lifetime of the speed
reducer.
The graph can be displayed by the following procedures.
1. Select {=PM} in the main menu.
2. Select {=PM(REDUCER)}.
3. Select {Display}.
– The pull down menu appears.