System Setup
9 - 261
3. For example, when the EXESP signal is changed from “Normal Open” to “Normal
Close”, the mark “” indicates the external emergency stop signal is in the normal state
(Normal Close) and the mark “” indicates the external emergency stop signal is being
input (Normal Open).
4. Select {WRITE} and then {CONFIRM} to enable the changed settings.
When the data is updated correctly, the status on the title line is changed from “NOT
DONE” to “DONE”.
NOTICE
When the ON/OFF settings of the input signals are changed, outputting the signals that
have been output normally may fail. This may lead to a serious accident. After changing the
ON/OFF settings of the input signals, be sure to confirm the safety logic circuit operates
normally.
6 PPDSW Programming pendant enable
switch signal
: Grip
: Not grip (SERVO OFF)
Programming pendant enable
switch signal
: Not grip (SERVO OFF)
: Grip
7 PPESP Programming pendant emergen-
cy stop signal
: Under emergency stop
: Normal)
Programming pendant emergen-
cy stop signal
: Normal
: Under emergency stop
8 SAFF Safety fence signal
: Open (safeguarding opened)
: Close
Safety fence signal
: Close/
: Open (safeguarding opened
No. Signal
name
Normal Open Normal Close