Ascotel IntelliGate 2025/2045/2065
198 Identification Elements Part 2
"Truncate CLIP" Setting
A digit sequence can be configured here. If the sequence matches the initial digits
of the CLIP number received, the digits will be truncated. This setting is normally
used to remove any superfluous "0".
"CLIP automatic" Setting
This setting is effective only if "Network type = private" has been set in the trunk
group configuration.
If "CLIP automatic = yes", the numbering plan identifier and type of number are
left unchanged.
If "CLIP automatic = no", the numbering plan identifier and type of number are
taken from the trunk group setting, but not the actual CLIP number. This may be
necessary in cases where connected third-party systems do not process number-
ing plan identifiers and types of number correctly.
Numbering Plan identifier, Type of Number, Number
These settings are used if the CLIP number could not be created automatically.
This is the case when there is no suitable DDI number available with a call to the
public network.
CLIP/CLIR settings
These settings are used to truncate prefixed access digits so that the CLIP number
is as short as possible.
To enable the PBX to interpret CLIP numbers correctly, the system's own regional
prefixes need to be entered under "CLIP/CLIR settings":
• International and national prefixes for the PBX locations ("00" and "0" for
Switzerland, "00" and "-" for France)
• Country code and long-distance code of the PBX location (for Switzerland
"41", for Geneva "22"", see also "Numbering Plan Identifier E.164", page
161).