Ascotel IntelliGate 2025/2045/2065
Part 7 Hardware updates and system expansion 911
10. If the configuration data was not transferred when changing the Flash card,
initialize the system and reload the configuration data using AIMS.
3.4.2 Uninterruptible power supply
The UPS-12V and DC-48V modules are connected with the mainboard via two 6-
pin connectors. Information on installation and removal can be found in "Unin-
terruptible power supply (UPS)", page 725.
3.5 Replacing system terminals
This chapter describes what to pay attention to when replacing terminals.
3.5.1 Corded system terminals
3.5.1.1 Terminals with the same level of added features
Replacing a defective terminal
Once the defective system terminal has been replaced by an identical terminal the
terminal configuration data is automatically transferred.
Relocating a terminal
The terminal configuration data of a system terminal can be copied to another ter-
minal with the same level of added features using the AIMS Configuration Man-
ager. The data can also be saved with AIMS and then reloaded if the system ter-
minal is logged on to a different card.
See also:
The procedure for saving configuration data with AIMS is described in
"Exchanging data between PBX and PC", page 153.