Ascotel IntelliGate 2025/2045/2065
388 Call logging (CL) Part 2
Explanation of the data fields
Subscriber number
Outgoing:
Entry for the caller’s subscriber number.
Entry for source PINX and stand-alone PBX; otherwise the data field remains
empty.
Incoming:
Contains an entry for source PINX and stand-alone PBX; otherwise the data
field remains empty.
Unanswered call:
The number for the internal destination address is entered here. It can be a user
group (UG), a key telephone (KT), a subscriber (SC) or a combination of these
addresses.
The SC number is entered here for SC and the combinations SC+UG or SC+KT.
The UG number is entered here for UG and the combination UG+KT, where
configured. If not, the configured ICL initialization number is entered, as with
the KT setting.
Answered call:
Enters the number of the caller who took the external call or rerouted it exter-
nally.
Transferred call:
If the call was transferred internally or externally, the transferred subscriber is
entered.
Destination number 2 DEST2 i SP -I 40 156
Time-To-Answer TTA i 0 -I 3 197
Sequence number SEQ.NO. i 0 -I 3 201
Serial number SERIAL NO. i 0 -I 4 205
Carriage Return (CR) 1 209
Line Feed (LF) 1210
Data field Name Data format Formatting Length Offset