Ascotel IntelliGate 2025/2045/2065
Part 2 Call logging (CL) 391
Tab. 2.93: Example of the output type "CL printer" in PC5 format
Date and time of start of connection
• Entry for the time of the start of connection at the logging PBX/PISN.
• In the case of forwarded calls the time logged is the time as of which the trans-
ferred call begins.
Duration of connection
• Entry for the duration of a connection by the logging PBX/PINX.
• The entry for unanswered calls is 0.
Call charges
• In the case of an ISDN connection, the call charge information supplied with
the call is entered here.
• In the case of an analogue connection, the metering pulses are converted and
entered.
Metering pulses
• In the case of an ISDN connection, the call charge information supplied with
the call is converted and entered.
• In the case of an analogue connection the metering pulses are entered.
NO CC SC DATE TIME DURATION CHARGES METPUL EXCH
50250 321 180598 14:56 00H01m12 00101
343 180598 14:57 00H02m05 00102
140 180598 15:05 00H10m35 00103
50001 321 180598 15:20 00H01m12 00201
ID1 ID2 DEST1 DEST2 TTA SEQ.NO
.
SERIAL
NO.
0222222200 022222222 50 0023 014 1236
0333330000 033333333 54 0012 015 1237
0333330000 0333330000 50301 54 1238
0333330000 0333330000 50301 0012 007 1239