Ascotel IntelliGate 2025/2045/2065
Part 2 Call logging (CL) 393
Caller identification 1, outgoing:
On the OCL report at the gateway/transit PINX: The subscriber call number valid
within the network is entered here.
On the OCL report at the source PINX no number is entered in this field.
Caller identification 2, outgoing:
On the OCL report at the source/transit PINX: The subscriber call number valid
within the PISN is entered here.
On the OCL report at the gateway PINX: The subscriber's DDI number is
entered here.
On a stand-alone PBX the entries are output analogue to a source PINX.
Fig. 2.134: Caller identification outgoing
Destination number 1 and destination number 2
These fields have a different meaning depending on the direction (incoming or
outgoing calls).
Destination number 1, incoming:
For incoming calls: no entry.
For calls to the DDI number for external remote control: Enter the instruction
sequence selected in DTMF mode.
PINX 1
Region 60
032 624 33 00
032 624 33 99
032 624 24 00
032 624 24 99
Caller ID1: 50 300
Caller ID2: 53
Caller ID1: –
Caller ID2: 50 300
Subscriber No. 300
DDI 53 — > Subscriber 50 300
Call
Logging
PC
Call
Logging
PC
DDI:54
haz0607aaena0
PBX
PINX 2
Region 50

Table of Contents