Ascotel IntelliGate 2025/2045/2065
548 Features Part 2
Tab. 2.306: Activating/deactivating functions via switch groups:
Note:
When switch groups are switched over, the functions are maintained in
their status at the time.
Available Functions
All remote-controlled functions can be activated with time control. User-specific
features are activated with *06 <SC No.>. For an overview of the functions avail-
able see Tab. 2.298 and Tab. 2.299. In addition to the remote-controlled features
the following functions can also be activated using time control:
Tab. 2.307: Additional time-controlled functions
No. */# pro-
cedure
Start
(Day)
Stop
(Day)
Execution
date
Execu-
tion time
Switch
group
Meaning
5 *931 Monday Friday 07:00 7 Activate Courtesy
6 #931 Monday Friday 18:00 7 Deactivate Courtesy
7 *8572 20.12.2002 18:30 Switching from switch group 7 to
switch position 2: All functions
allocated switch group 7 are
deactivated.
8 *8571 06.01.2003 06:30 Switching from switch group 7 to
switch position 1: All functions
allocated switch group 7 are acti-
vated.
Feature Activate Reset
Activate / clear Courtesy *93<group>. #93<group>
Enable/bar a one-off remote access *754, #754
Enable/bar a permanent remote access *753 #753