Vol. VI-B-12 Alcatel-Lucent
Date and Time Not Set
Date and time have not been set. This is a warning alarm.
Probable Cause
Configuration incomplete.
Recommended Actions
Use the CT Date/Time screen to configure the settings.
Slot Plug-in Missing
Cannot detect a plug-in in a configured slot. This is a major alarm.
Probable Cause
Plug-in is not installed in a configured slot.
Recommended Actions
1. If the slot is correctly configured, insert the required plug-in.
2. If the slot should be empty, accept the empty status in the CT System
Summary screen.
Slot Plug-in Incorrect
Plug-in incorrect for the slot configuration. This is a major alarm.
Probable Cause
Wrong plug-in in slot, or slot configuration incorrect for the plug-in.
Recommended Actions
1. If the slot configuration is correct, install the correct plug-in.
2. If the installed plug-in is correct, accept the plug-in in the CT System
Summary screen, then configure the plug-in.
TDM Clock Locked to NCC
TDM clock is locked to the NCC. This is a warning alarm.
Probable Cause
TDM bus clock has been locked to the NCC using the lock command in CT
System Controls.