9500 MXC User Manual
3DB 23063 ADAA - Rev 004 July 2007 Vol. VI-B-13
Recommended Actions
To remove the alarm, remove the lock.
Additional Information
This alarm will only present when an NPC has been installed and the lock is
applied.
Circuit Loopback
Circuit loopback has been applied. This is a warning alarm.
Probable Cause
A loopback is active - set in the Circuit Loopbacks screen.
Recommended Actions
Remove the loopback.
NMS Configuration Error
Error in the NMS configuration. This is a major alarm.
Probable Cause
Error in the NMS configuration.
Recommended Actions
Check NMS configuration.
NMS Over AUX Channel n Failure
No communication via the NMS over the AUX channel. This is a major alarm.
Probable Cause
Equipment malfunction.
Recommended Actions
Check the integrity of the connected equipment.
Check the AUX card operation and setup.