EasyManua.ls Logo

Alcatel-Lucent 9500 MXC - Page 781

Alcatel-Lucent 9500 MXC
916 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9500 MXC User Manual
3DB 23063 ADAA - Rev 004 July 2007 Vol. VI-B-55
Check remote-end mux/regenerator operation.
Additional Information
Occurs when an OOF state persists, typically for 3 mS. Clears when an in-frame
condition exists continuously - typically 3 milliseconds.
OOF
Out of Frame (OOF) alarm detected in the regenerator. This is a critical alarm.
Probable Cause
Pier equipment malfunction.
Recommended Actions
Check presence of other alarms.
Check operation of the remote-end mux/regenerator.
Additional Information
Occurs when consecutive frames (typically 4-5) are received with errored
patterns (A1/A2 bytes). Max time to detect is 625 uS - clears within 250 uS when
two consecutive frames are received with valid framing.
Container x AIS
AIS detected in container x. This is a minor alarm.
Probable Cause
Signal source for this container is not present.
Recommended Actions
Check the remote-end signal source.
Additional Information
Alarm is raised for ‘All 1’s in pointer bytes H1 and H2 for three consecutive
frames.
Container x LOP
Loss of Pointer (LOP) detected in container x. This is a major alarm.

Table of Contents