Error code Error Measure
U5002
Implement and track line are not
defined.
Select the correct implement again,
see page
86.
Check whether the correct field was
added to the job; see page .
Select the correct job again; see
page 121.
Create new track line; see page 146
U5003
Steering control could not be switched
on because
of the steering control
lock.
Disable the lock switch for road
transport.
U5004 No implement defined.
Select the correct implement; see
page
86:
U5007
Row spacing (working width minus
overlap
of the implement) is too small.
Reduce the degree of overlap for
automatic part-width section control;
see page 186:
U6904
Only one steering controller, but
vehicle
type is articulated.
Check the vehicle configuration; see
page 71.
U6905 Unknown implement type.
Check the vehicle configuration; see
page
71.
U8505 No factory calibration. Calibrate steering; see page 166.
TC8
Inertial sensor and modem are not
supplied
with 12 V voltage.
Check all connectors and
connections.
2
Calling up the system diagnosis
In the function menu, there is a miniature view that
provides
information on the system properties of the
AMAPAD.
In the function menu, tap on .
The miniature view will be opened.
005295
T | Troubleshooting| Calling up the system diagnosis
MG5574-EN-II | B.1 | 25.10.2016
224