SIP User's Manual 104 Document #: LTRT-83310
Mediant 600 & Mediant 1000
2. Under the 'Multiple Interface Settings' group, click the Multiple Interface Table
button; a confirmation message box appears:
Figure 10-2: Confirmation Message for Accessing the Multiple Interface Table
3. Click OK to confirm; the 'Multiple Interface Table page appears:
4. In the 'Add Index' field, enter the desired index number for the new interface, and then
click Add Index; the index row is added to the table.
5. Configure the interface according to the table below.
6. Click the Apply button; the interface is added to the table and the Done button
appears.
7. Click Done to validate the interface. If the interface is not valid (e.g., if it overlaps with
another interface in the table or if it does not adhere to the other rules as summarized
in 'Multiple Interface Table Configuration Summary and Guidelines' on page 112), a
warning message is displayed.
8. Save the changes to flash memory and reset the device (see 'Saving Configuration' on
page 482).
To view network interfaces that are currently active, click the IP Interface Status Table
button. For a description of this display, see 'Viewing Active IP Interfaces' on page
517.
Table 10-1: Multiple Interface Table Parameters Description
Parameter Description
Table parameters
Index
Table index row of the interface.
The range is 0 to 15.
Web: Application Type
EMS: Application Types
[InterfaceTable_Applicatio
nTypes]
Defines the types of applications allowed on the interface.
[0] OAMP = Operations, Administration, Maintenance and
Provisioning (OAMP) applications (e.g., Web, Telnet, SSH, and
SNMP).
[1] Media = Media (i.e., RTP streams of voice).
[2] Control = Call Control applications (e.g., SIP).
[3] OAMP + Media = OAMP and Media applications.
[4] OAMP + Control = OAMP and Call Control applications.