EasyManua.ls Logo

AudioCodes Mediant 600 - Page 690

AudioCodes Mediant 600
844 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIP User's Manual 690 Document #: LTRT-83310
Mediant 600 & Mediant 1000
Parameter Description
DialPlanFileName = 'DialPlan_USA.dat'
CASTrunkDialPlanName_5 = 'AT_T'
[CASFileName_x]
Defines the CAS file name (e.g., 'E_M_WinkTable.dat') that defines
the CAS protocol, where x denotes the CAS file ID (0-7). It is
possible to define up to eight different CAS files by repeating this
parameter. Each CAS file can be associated with one or more of
the device's trunks, using the parameter CASTableIndex_x.
Note: For this parameter to take effect, a device reset is required.
Web: CAS Table per Channel
[CASChannelIndex]
Defines the loaded CAS protocol table index per B-channel
pertaining to a CAS trunk. This parameter is assigned a string
value and can be set in one of the following two formats:
CAS table per channel: Each channel is separated by a
comma and the value entered denotes the CAS table index
used for that channel. The syntax is <CAS index>,<CAS index>
(e.g., "1,2,1,2…"). For this format, 31 indices must be defined
for E1 trunks (including dummy for B-channel 16), or 24 indices
for T1 trunks. Below is an example for configuring a T1 CAS
trunk (Trunk 5) with several CAS variants
ProtocolType_5 = 7
CASFILENAME_0='E_M_FGBWinkTable.dat'
CASFILENAME_1='E_M_FGDWinkTable.dat'
CASFILENAME_2='E_M_WinkTable.txt'
CasChannelIndex_5 =
‘0,0,0,1,1,1,2,2,2,0,0,0,1,1,1,0,1,2,0,2,1,2,2,
2’
CASDelimitersPaddingUsage_5 = 1
CAS table per channel group: Each channel group is
separated by a colon and each channel is separated by a
comma. The syntax is <x-y channel range>:<CAS table index>,
(e.g., "1-10:1,11-31:3"). Every B-channel (including 16 for E1)
must belong to a channel group. Below is an example for
configuring an E1 CAS trunk (Trunk 5) with several CAS
variants:
ProtocolType_5 = 8
CASFILENAME_2='E1_R2D'
CASFILENAME_7= E_M_ImmediateTable_A-Bit.txt'
CasChannelIndex_5 = ‘1-10:2,11-20:7,21-31:2’
Notes:
To configure this parameter, the trunk must first be stopped.
Only one of these formats can be implemented; not both.
When this parameter is not configured, a single CAS table for
the entire trunk is used, configured by the parameter
CASTableIndex.
[CASTablesNum]
Defines how many CAS protocol configurations files are loaded.
The valid range is 1 to 8.
Note: For this parameter to take effect, a device reset is required.
CAS State Machines Parameters
Note: For configuring the CAS State Machine table using the Web interface, see 'Configuring CAS
State Machines' on page 231.
Web: Generate Digit On Time
[CASStateMachineGenerateDi
gitOnTime]
Generates digit on-time (in msec).
The value must be a positive value. The default value is -1.