Version 6.4 691 March 2012
SIP User's Manual A. Configuration Parameters Reference
Parameter Description
Web: Generate Inter Digit Time
[CASStateMachineGenerateIn
terDigitTime]
Generates digit off-time (in msec).
The value must be a positive value. The default value is -1.
Web: DTMF Max Detection
Time
[CASStateMachineDTMFMax
OnDetectionTime]
Detects digit maximum on time (according to DSP detection
information event) in msec units.
The value must be a positive value. The default value is -1.
Web: DTMF Min Detection Time
[CASStateMachineDTMFMinO
nDetectionTime]
Detects digit minimum on time (according to DSP detection
information event) in msec units. The digit time length must be
longer than this value to receive a detection. Any number may be
used, but the value must be less than
CasStateMachineDTMFMaxOnDetectionTime.
The value must be a positive value. The default value is -1.
Web: MAX Incoming Address
Digits
[CASStateMachineMaxNumOf
IncomingAddressDigits]
Defines the limitation for the maximum address digits that need to
be collected. After reaching this number of digits, the collection of
address digits is stopped.
The value must be an integer. The default value is -1.
Web: MAX Incoming ANI Digits
[CASStateMachineMaxNumOf
IncomingANIDigits]
Defines the limitation for the maximum ANI digits that need to be
collected. After reaching this number of digits, the collection of ANI
digits is stopped.
The value must be an integer. The default value is -1.
Web: Collect ANI
[CASStateMachineCollectANI]
In some cases, when the state machine handles the ANI collection
(not related to MFCR2), you can enable the state machine to
collect ANI or discard ANI.
[0] No = Don't collect ANI.
[1] Yes = Collect ANI.
[-1] Default = Default value.
Web: Digit Signaling System
[CASStateMachineDigitSignal
ingSystem]
Defines which Signaling System to use in both directions
(detection\generation).
[0] DTMF = Uses DTMF signaling.
[1] MF = Uses MF signaling (default).
[-1] Default = Default value.