Table 6.9.1 finished
Failure,
external manifestation, cause
Troubleshooting
Wobbling of steering wheels when moving
Conic-shaped pins of the HSC hy-
draulic cylinders or of the steering
link are not tightened
Tighten pin nuts
There is a play in the steering link
joints
Eliminate the play in the steering link joints, as outlined
in Section 5 “Maintenance
Mechanical connections or bearings
are worn out
Replace the worn-out components
Air presence in the HSC hydraulic
system
Bleed air from the HSC hydraulic system by turning the
steering wheel moving guide wheels from the left-most
to the right-most position (stop-to-stop position) for 2-3
times
Break of dosing pump air tightness over spool end,
over connection of casinggerotor pair cover
Wear of spool sealing
Contact the dealer. Replacement of faulty sealing, as-
sembly and check of operability shall be performed only
by maintenance department in accordance with manu-
facturer’s instruction
1)
Loose bolts of dosing-pump cover
Tighten the bolts with a torque of 30 to 35 Nm
Different minimum radii of tractor turning to the left and to the right
Alignment of front wheels is not ad-
justed
Adjust the alignment of front wheels as outlined in Sec-
tion 5 “Maintenance
Incomplete turning angle of steering wheels
Insufficient pressure in the HSC hy-
draulic system due to the following
reasons:
-
faulty adjustment of dosing pump
safety valve (low pressure)
- faulty feed pump (the pump fails
to increase pressure because of low
efficiency factor)
Contact the dealer. It is required to adjust the safety
valve for the required pressure
1)
.
Contact the dealer to replace or repair the pump.
Increased FDA reduction gear steer-
ing torque
Repair the FDA
Breakdown of feed pump
High pressure in the HSC hydraulic
system due to jamming of the dosing
pump safety valve in the closed po-
sition (possibly due to dirt accumula-
tion)
Contact the dealer. Rinse of dosing-pump components
is required. Assembly, adjustment of the safety valve for
the required pressure and check of operability shall be
performed by maintenance department in accordance
with manufacturer’s instruction
1)
Replace the broken
feed pump.
____________________________________________________________________________
1)
Considering extreme complexity and responsibility of the dosing pump from the viewpoint of the steer-
ing system safety, its disassembly and assembly shall be carried out only by servicing personnel of
man
ufacturing company (or other authorized maintenance department), properly trained, who have
studied dosing pump structure and service manuals as well as assembly-disassembly manuals, and
provided they have all required service tools, accessories and special hydraulic stand, ensuring adjust-
ment and check of dosing pump parameters and operability after the repairs that have been made. Oth-
erwise, a person performing the dosing pump assembly and disassembly, replacement of parts and
components or adjustment of valves, as well as the tractor owner, will bear full responsibility for dosing
pump non-operability.