The mode “Date/time” allows to display and change the current time and date. Adjust-
ing the current time is available in 24h format. The current date is adjusted in DD.MM.YY for-
mat.
When the wires from the battery are disconnected and then re-connected, after the
voltage supply is restored, these parameters are reset to their initial value (“08:00”,
“01.01.2017”).
When the battery is disconnected by means of the battery switch, the current
“Date/Time” values are not reset to the initial values.
In the mode “Functions test” a testing of needle indicators and signal annunciators of
the instrument panel and HPC is performed.
In the “Language selection” mode (“Выбор языка”), the language of instrument panel
display is selected (Russian or English).
In the mode “Units of measurement”, the measurement units for parameters can be
changed. Units for travel speed, pressure, temperature and volume can be selected. The list of
measurement units of parameters is given in table 2.6.4.
Table 2.6.4 – Units of measurement for parameters
Parameter
Unit of measurement
Travel speed
km/h, МРН
Pressure
kPa, Bar, psi
Temperature
°С, °F
Volume
l, Gal
The mode “Sensors adjustment” allows switching to the mode of adjusting the tractor
sensors. This mode also allows enabling and disabling of displaying the following indicators on
the instrument panel:
- Oil pressure indicator;
- air pressure indicator;
- oil pressure in transmission indicator;
- green sector of oil pressure in transmission.
Introduction of changes is possible only after entering the password. If it is necessary to
change the settings, address your dealer. The list of all adjustable coefficients and their values
in given in table 2.6.5.
Table 2.6.5 – List of adjustable coefficients and their values
Coefficient Coefficient name Fixed values
Range of non-
fixed values
Values for
tractors BEL-
ARUS-82.3»
Z
Number of teeth of rear
wheel final drive gear
23, 54, 56, 69
from 0 to 99
sensitivity 1
69
ZV
Number of gear teeth in
place of RPTO speed sen-
sor installation
12, 15, 78, 86
from 0 to 99
sensitivity 1
12
ZV2
Number of gear teeth in
place of FPTO speed sen-
sor installation
0, 12
from 0 to 99
sensitivity 1
0
I
Transmission ratio of wheel
reduction gear
1.00, 3.34, 4.00
from 0 to 5.00
sensitivity 0.01
1.00
R
k
Rolling radius of rear
wheel, mm
-
from 400 to 999
sensitivity 5
770 (for tires
18.4R34)
К
Transmission ratio of
alternator and crankshaft
pulleys
2.36, 2.42, 3.00
from 2.00 to 4.00
sensitivity 0.01
2.36
V Fuel tank volume, l
85, 125, 140, 265,
510, 650
from 1 to 999 125
This mode enables entering a fixed value for the coefficient from the number of values
from table 2.6.5 as well as entering a non-fixed value within the specified ranges.