Table 6–25: Set up of sequence send telegram for the RK512 protocol as implemented in the tightening system.
Protocol CS351
(PLC)
Value PLC
(CS351)
Meaning
Name Hex
Sequence telegram 3964R STX 02 Start character
DLE 10 Positive acknowledgement
Sequence telegram
header
1. Byte ff Sequence telegram ID
2. Byte 00 ID
3. Byte 41 Command SEND "A"
4. Byte 44 Data element "D"
Data 11. Byte 1 Data byte
12. Byte 2 Data byte
…
…
Xth byte n. Nth data byte (128 n)
3964R DLE 10 End ID
ETX 03 End ID
BCC Block check sum
DLE 10 Positive acknowledgement
Reaction telegram 3964R STX 02 Start character
DLE 10 Positive acknowledgement
Telegram header 1. Byte 00 ID
2. Byte 00 ID
3. Byte 00
4. Byte 00 Error number
3964R DLE 10 End ID
ETX 03 End ID
BCC Block check sum
DLE 10 Positive acknowledgement
Table 6–26: Telegram setup for the 3964R protocol with a telegram header as implemented in the tightening system.
Protocol CS351/
KE350
(PLC)
Value PLC
(CS351/
KE350)
Meaning
Name Hex
3964R STX 02 Start character
DLE 10 Positive acknowledgement
Telegram header 1. Byte 00 ID
2. Byte 00 ID
3. Byte 41 Command SEND "A"
4. Byte 44 Data element "D"
5. Byte 0a Data element no., e. g. DE 10=0a hex
6. Byte 80 Data word no., e.g. DW 64=80 hex
7. Byte 00 Number
e.g. 50 DW (= 32 hex)
8. Byte 32
9. Byte ff No CT
10. Byte ff All CPUs
Data 11. Byte 1 Data byte
12. Byte 2 Data byte
…
…
Xth byte n. Nth data byte (128 n)
3964R DLE 10 End ID
ETX 03 End ID
BCC Block check sum
DLE 10 Positive acknowledgement