15 1 Int8 Reserve (00 hex)
16 64 String ID code
80 4 Int32 Torque actual value
84 4 Int32 Angle actual value
88 4 Int32 Torque threshold actual value
92 4 Int32 Gradient actual value
96 4 Int32 Deviation torque actual value/redundancy value
100 4 Int32 Deviation angle actual value/redundancy value
104 4 Int32 Torque+ set value
108 4 Int32 Torque- set value
112 4 Int32 Angle+ set value
116 4 Int32 Angle- set value
120 4 Int32 Gradient+ set value
124 4 Int32 Gradient- set value
128 4 Int32 Redundancy torque set value
132 4 Int32 Redundancy angle set value
Table 6–34: Result of a single-channel tightening process (binary format)
Rel. byte address Length Format Contents
Total: 136 bytes
Table 6–35: Application result (ASCII format)
Rel. byte address Length Format Contents
0 1 Int8 Application no.
1 1 Int8 Result (1 = OK, –1 = NOK, 0 = invalid)
21Int8Quality code
3 1 ASCII Reserve (00 hex)
44ASCIIYear
82ASCIIMonth
10 2 ASCII Day
12 2 ASCII Hours
14 2 ASCII Minutes
16 2 ASCII Seconds
18 64 ASCII ID code
82 1 Int8 Number of tightening positions
83 1 ASCII Reserve (00 hex)
Total: 84 bytes
Table 6–36: Tightening position result (ASCII format)
Rel. byte address Length Format Contents
0 4 ASCII Rack/slot no. (e.g. "10.4")
4 1 Int8 Tightening program no.
5 1 Int8 Application no.
6 1 Int8 Result (1 = OK, –1 = NOK, 0 = invalid)
71Int8Quality code
8 3 ASCII Line / column of the results step (e.g. "3A")
11 1 ASCII Reserve (00 hex)
12 8 ASCII Torque actual value
1
20 8 ASCII Angle actual value
1
28 8 ASCII Torque threshold actual value
1
36 8 ASCII Gradient actual value
1
44 8 ASCII Deviation torque actual value/redundancy value
1
52 8 ASCII Deviation angle actual value/redundancy value
1
60 8 ASCII Torque+ set value
1
68 8 ASCII Torque- set value
1
Total: 124 bytes