ASCII format 2
76 8 ASCII Angle+ set value
1
84 8 ASCII Angle- set value
1
92 8 ASCII Gradient+ set value
1
100 8 ASCII Gradient- set value
1
108 8 ASCII Redundancy torque set value
1
116 8 ASCII Redundancy angle set value
1
1 If the tightening channel is in the "Bypass" condition (see "Project planning" documentation of the Rexroth
Tightening System 350), these result data are output with a space character (hexadecimal value "0x20"). In this,
the quality code within the result (rel. byte address = 7) indicates whether the tightening channel is in "Bypass"
condition.
Table 6–37: Result of a single-channel tightening process (ASCII format)
Rel. byte address Length Format Contents
0 4 ASCII Rack/slot no. (e.g. "10.4")
4 1 Int8 Tightening program no.
5 1 Int8 Result (+1 = OK, –1 = NOK, 0 = invalid)
61Int8Quality code
7 1 ASCII Reserve (00 hex)
8 3 ASCII Line / column of the results step (e.g. "3A")
11 1 ASCII Reserve (00 hex)
12 4 ASCII Year
16 2 ASCII Month
18 2 ASCII Day
20 2 ASCII Hours
22 2 ASCII Minutes
24 2 ASCII Seconds
26 64 String ID code
90 8 ASCII Torque actual value
98 8 ASCII Angle actual value
106 8 ASCII Torque threshold actual value
114 8 ASCII Gradient actual value
122 8 ASCII Deviation torque actual value/redundancy value
130 8 ASCII Deviation angle actual value/redundancy value
138 8 ASCII Torque+ set value
146 8 ASCII Torque- set value
154 8 ASCII Angle+ set value
162 8 ASCII Angle- set value
170 8 ASCII Gradient+ set value
178 8 ASCII Gradient- set value
186 8 ASCII Redundancy torque set value
194 8 ASCII Redundancy angle set value
Total: 202 bytes
Table 6–36: Tightening position result (ASCII format)
Rel. byte address Length Format Contents
Total: 124 bytes
Table 6–38: KE application result (ASCII format 2)
Rel. byte address Length Format Contents
0 2 ASCII Application no.
2 2 ASCII Result (1 = OK, –1 = NOK, 0 = invalid)
4 5 ASCII Quality code
9 1 ASCII Reserve (20 hex = space characters)
10 4 ASCII Year
Total: 90 bytes