280/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
14 2 ASCII Month
16 2 ASCII Day
18 2 ASCII Hours
20 2 ASCII Minutes
22 2 ASCII Seconds
24 64 ASCII
1
ID code
88 2 ASCII Number of tightening positions
1 Space characters (20Hex) are added to the string, if needed.
Table 6–39: Tightening position result (ASCII format 2)
Rel. byte address Length Format Contents
0 4 ASCII Rack/slot no. (e.g. "10.4")
4 2 ASCII Tightening program no.
6 2 ASCII Application no.
8 2 ASCII Result (1 = OK, –1 = NOK, 0 = invalid)
10 8 ASCII
1
1 If necessary, the character string is filled with spaces (hexadecimal value "0x20").
Production number
(first 8 characters in the ID code)
18 4 ASCII
1
Location ID / station ID
(the first 4 characters of the location name of administration level 7)
22 4 ASCII
1
Tightening position designation
(the first 4 characters of the tightening position name)
26 5 ASCII Quality code
31 1 ASCII Reserve (20 hex = space characters)
32 3 ASCII
1
Line / column of the results step (e.g. "3A")
35 1 ASCII Reserve (20 hex = space characters)
36 8 ASCII Torque- set value
2
2 If the tightening channel is in the "Bypass" condition (see "Project planning" documentation of the Rexroth
Tightening System 350), these result data are output with a space character (hexadecimal value "0x20"). In this,
the quality code within the result (rel. byte address = 26) indicates whether the tightening channel is in "Bypass"
condition.
44 8 ASCII Torque actual value
2
52 8 ASCII Torque+ set value
2
60 8 ASCII Angle- set value
2
68 8 ASCII Angle actual value
2
76 8 ASCII Angle+ set value
2
84 8 ASCII Deviation torque actual value/redundancy value
2
92 8 ASCII Redundancy torque set value
2
Total: 100 bytes
Table 6–40: Tightening position result (ASCII format 2)
Rel. byte address Length Format Contents
0 4 ASCII Rack/slot no. (e.g. "10.4")
4 2 ASCII Tightening program no.
6 2 ASCII Result (+1 = OK, –1 = NOK, 0 = invalid)
88ASCII
1
Production number
(first 8 characters in the ID code)
16 4 ASCII
1
Location ID / station ID
(the first 4 characters of the location name of administration level 7)
20 4 ASCII
1
Tightening position designation
2
Total: 98 bytes
Table 6–38: KE application result (ASCII format 2)
Rel. byte address Length Format Contents
Total: 90 bytes