3 608 878 300 Tightening Technology | Bosch Rexroth AG 281/641
System 350 | 3 608 878 300/2019-03
6.3.4.8 Data sets and assignment to data elements
The results formats described in section 6.3.4.7 come from the data sets listed in Table 6–41.
For tightening applications and associated tightening position results, these data quantities are rounded
to the next power of two (e.g. 60 26 = 64), to enable better assignment of the memory areas.
24 5 ASCII Quality code
29 1 ASCII Reserve (20 hex = space characters)
30 3 ASCII
1
Line / column of the results step (e.g. "3A")
33 1 ASCII Reserve (20 hex = space characters)
34 8 ASCII Torque- set value
42 8 ASCII Torque actual value
50 8 ASCII Torque+ set value
58 8 ASCII Angle- set value
66 8 ASCII Angle actual value
74 8 ASCII Angle+ set value
82 8 ASCII Deviation torque actual value/redundancy value
90 8 ASCII Redundancy torque set value
1 Space characters (20Hex) are added to the string, if needed.
2 A tightening position designation exists only in application operation on the SE
Table 6–40: Tightening position result (ASCII format 2)
Rel. byte address Length Format Contents
Total: 98 bytes
Table 6–41: Data quantities in bytes
Format Results values Application Tightening position Single channel
Binary Actual values 78 (128) 32 (32) 104
Actual and set values 78 (128) 64 (64) 136
ASCII Actual values 84 (128) 60 (64) 138
Actual and set values 84 (128) 124 (128) 202
ASCII format
2
Actual and set values 90 (128) 100 (128) 98