EasyManua.ls Logo

Bosch Rexroth Tightening System 350 - Page 351

Bosch Rexroth Tightening System 350
641 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 608 878 300 Tightening Technology | Bosch Rexroth AG 351/641
System 350 | 3 608 878 300/2019-03
MID 0014 Subscription to tightening program/tightening application selected
Maximum angle The value consists of five ASCII characters.
ID 09
2
Value range 00000 99999
Presetting -
Example:
Maximum angle 45
Value 00045
5
Target angle The target angle is output in degrees.
The value consists of five ASCII characters.
ID 10
2
Value range 00000 99999
Presetting -
Example:
Target angle 40
Value 00040
5
Data length revision 001
84
Table 6–82: MID 0013 revision 001
Parameter Comments Bytes
Sent by: superordinate computer
A message (tightening program selected, MID 0015) is sent to the superior computer each time a new tightening
program or tightening application is selected. This message is also sent as a direct answer to the activation message,
after the response (command accepted, MID 0005) has been sent.
Note:
Supported systems and OP variants:
CS351 compact system: This function is supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW,
and sends the appropriate data to the superior computer each time the tightening program is changed.
Modular system: This function is only supported for the KE350 (spindle "00") and not for the connected tightening
spindles (only application operation with the modular system). The appropriate data are sent to the superior
controller each time the application program in application block 1 is changed. The information "Date of the last
change in the program setting" is read out from the data of the selected application.
Revision: 001
System Supported by
CS351 compact
system
Rexroth OP, Rexroth OP-Ford, Rexroth OP-BMW
Modular system
KE350
Rexroth OP-Ford
Data field: is empty, 0 bytes
Possible responses MID Error no. Comment
Command accepted 0005
Command error 0004 13 Subscription for tightening program/tightening
application selection already available

Table of Contents

Related product manuals