3 608 878 300 Tightening Technology | Bosch Rexroth AG 353/641
System 350 | 3 608 878 300/2019-03
MID 0016 Acknowledge tightening program/tightening application selected
MID 0017 Cancel subscription to tightening program/tightening application selected
MID 0018 Select tightening program/tightening application
Sent by: superordinate computer
Acknowledge selection of a new tightening program or tightening application
Note: -
Revision: 001
System Supported by
CS351 compact
system
Rexroth OP, Rexroth OP-Ford, Rexroth OP-BMW
Modular system
KE350
Rexroth OP-Ford
Data field: is empty, 0 bytes
Possible response: none
Sent by: superordinate computer
Reset subscription to the tightening program or tightening application selection
Note: -
Revision: 001
System Supported by
CS351 compact
system
Rexroth OP, Rexroth OP-Ford, Rexroth OP-BMW
Modular system
KE350
Rexroth OP-Ford
Data field: is empty, 0 bytes
Possible responses MID Error no. Comment
Command accepted 0005
Command error 0004 14 Subscription to tightening program/tightening
application selection not available
Sent by: superordinate computer
Select tightening program or tightening application
Note:
CS351 compact system: Program selection via Open Protocol can only be made when the PLC signals Prog0–
Prog7 are applied to the Open Protocol module (OP 0.0 - OP 0.7) in the PLC table.
Modular system KE350: Application selection via Open Protocol can only be made when the PLC signals Seq0–
Seq7 are applied to the Open Protocol module (OP 0.0 - OP 0.7) in the PLC table.
Revision: 001
System Supported by
CS351 compact
system
Rexroth OP, Rexroth OP-Ford, Rexroth OP-BMW
Modular system
KE350
Rexroth OP-Ford
Data field: Tightening program/tightening application selection, 3 ASCII characters (000 – 999), 3 bytes
Possible responses MID Error no. Comment
Command accepted 0005
Command error 0004 03 Tightening program/tightening application cannot
be selected