3 608 878 300 Tightening Technology | Bosch Rexroth AG 355/641
System 350 | 3 608 878 300/2019-03
MID 0020 Reset the OK counter
MID 0021
Deactivate the OK counter
1)
6.7.7.6 Job messages
MID 0030 OK counter upload request
MID 0030 Job number upload request
Job numbers upload is requested if the configuration for Open Protocol MID31 provides jobs list is
selected.
Sent by:
superordinate computer
This message allows to reset the OK counter for the counter value specified in the command ("Tightening program
number" parameter)
Note: The current counter values for all programs will be reset.
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: tightening program number, three ASCII characters (000–999), 3 bytes
Possible responses MID Error no. Comment
Command accepted 0005 –
Command error 0004 01
04
Invalid data
Tightening program not active
1) This message is supported from version V2.200 of the Rexroth Tightening System 350.
Sent by: superordinate computer
This message deactivates the OK counter for all tightening programs.
Note: All counters of all programs are switched off.
Revision: 001 (only supported by Rexroth OP and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible responses MID Error no. Comment
Command accepted 0005 –
Sent by: superordinate computer
All configured OK counters (0 to 99) in the tightening system are transferred as a result of this request.
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
OK counter upload response 0031 –
Sent by: superordinate computer
Request of all available job numbers
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
Job numbers upload response 0031 – All valid job numbers in the controller/
communication unit are transferred as a result of
this command.