356/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
MID 0031 OK counter upload response
MID 0031 Job numbers upload response
Job numbers upload response is provided if the configuration for Open Protocol MID31 provides jobs
list is selected.
MID 0031 revision 001
Sent by:
Tightening controller
Transfer of all configured OK counters (0 ... 99) in the tightening system.
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field:
Total data field length = (1 + number of configured OK counters) x 2 bytes.
Possible response: none
Table 6–86: MID 0031 revision 001
Parameter Comments Bytes
Number of configured
OK counters
The value consists of two ASCII characters.
ID -
Value range 00 – 99
Presetting -
Example:
Two configured OK counters 02
Value 02
2
OK counter number The value consists of two ASCII characters.
ID -
Value range 00 – 99
Presetting -
Example:
2 OK counter numbers 25.36
Value 2536
4
Data length revision 001 (with a configured OK counter)
6
Sent by: Tightening controller
Transfer of all available job numbers from the tightening controller.
Note: Only 2-digit job numbers are reported up. Job numbers >99 cannot be requested here.
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field:
Total data field length = (2 + 2x number of the valid job).
Possible response: none
Table 6–87: MID 0031 revision 001
Parameter Comments Bytes
Number of configured
Jobs
The value consists of two ASCII characters.
ID -
Value range 00 – 99
Presetting -
Example:
A configured job 01
Value 01
2