MID 0032 Job data upload request
MID 0033 Job data upload response
Job number Number of the first 100 jobs.
The value consists of two ASCII characters.
ID -
Value range 00 99
Presetting -
Example:
Job number 01
Value 01
2
Data length revision 001
4
Table 6–87: MID 0031 revision 001
Parameter Comments Bytes
Sent by: superordinate computer
Request to upload the parameters of a job.
Note: -
Revision:
001 (supported by Rexroth OP)
Data field: Job number, 2 bytes
Possible response: MID Error no. Comment
Job numbers upload response 0033 - All valid job data in the controller/communication
unit is transferred as a result of this command.
Command error 0004 02 Job not available.
Sent by: Tightening controller
Transmission of the job parameters of the selected job.
Note: -
Revision:
001 (supported by Rexroth OP)
Data field:
Total data length: (71 + 12 x number of tightening programs)
Possible response: none
Table 6–88: MID 0033 revision 001
Parameter Comments Bytes
Job number Job number
The value consists of two ASCII characters.
ID 01
2
Value range 00 99
Presetting -
Example:
Job number 01
Value 01
2
Job name The program name is output. Fill with space characters if the job name is
< 25 characters.
The value consists of 25 ASCII characters.
ID 02
2
Value range 0x20 – 0x7F
Presetting -
Example:
Job name Job1
Value Job1
25