EasyManua.ls Logo

Bosch Rexroth Tightening System 350 - Page 368

Bosch Rexroth Tightening System 350
641 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
368/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
MID 0052 revision 999
ID code part 3 Contains characters 51 64 of the ID code. The rest of the characters
are filled with space characters.
The value consists of 25 ASCII characters.
ID 03
2
Value range 0x20 – 0x7F
Presetting -
Example:
ID code part 3 11112222333344
Value
11112222333344+0x00+0x00+0x00+0x00
+0x00+0x00+0x00+0x00+0x00+0x00+0x0
0
25
ID code part 4 Only contains empty spaces.
The value consists of 25 ASCII characters.
ID 04
2
Value range
Presetting -
Example:
ID code part 4
Value 0x00+0x00+0x00+0x00+0x00+0x00+0x00+0x00
+0x00+0x00+0x00+0x00+0x00+0x00+0x00+0x0
0+0x00+0x00+0x00+0x00+0x00+0x00+0x00+0x
00+0x00
25
Data length revision 002 (= data length revision 001 + data length revision 002)
108
Table 6–95: MID 0052 revision 002
Parameter Comments Bytes
Characters that are not required in the value of length 25 must be filled with "\0" or 0x00. If empty spaces
are filled in, the "Attach sequence counter to ID code" function will fail to function properly in the
tightening controller.
Table 6–96: MID 0052 revision 999
Parameter Comments Bytes
ID code source This revision includes the information from revision 002 and the following
additional information:
The value consists of 4 ASCII characters.
The number is hexadecimally coded (32 bit).
ID code source numbering see table 6–97.
ID 05
2
Value range 0x30 0x39
0x41 0x46
0x61 0x66
Presetting -
Example:
ID code source 0011
Value 0x30 + 0x30 + 0x31 + 0x31
4
Data length revision 999
114

Table of Contents