3 608 878 300 Tightening Technology | Bosch Rexroth AG 401/641
System 350 | 3 608 878 300/2019-03
6.7.7.10 System error messages
MID 0070 Resulting system errors subscription
MID 0071 Upload resulting system errors
MID 0071 revision 001
Sent by:
superordinate computer
A subscription for the system errors that can be reported on the tightening controller.
Note: After successful subscription, a status message (MID 0076) will be sent to the superordinate computer for
each active error in the controller.
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible responses MID Error no. Comment
Command accepted 0005
Command error 0004 11 Activation of system errors already available
Sent by: Tightening controller
If a system error occurs in the tightening controller, it will be reported to the superior computer.
Note: -
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: Data 33 bytes
Possible response: none
Table 6–108: MID 0071 revision 001
Parameter Comments Bytes
Error number The error number consists of four ASCII characters.
ID 01
2
Value range 0000 9999
Presetting -
Example:
Error number 105
Value 0105
4
Controller ready status Always NOK (=0), as no differentiation is made between controller and
tool.
The value consists of one ASCII character.
ID 02
2
Fixed value 0
1
Tool ready status Only NOK if error comes from the tool (error code from measurement
transducer 200 to 299 or ErgoSpin 350 to 399).
–1: OK
–0: NOK
The value consists of one ASCII character.
ID 03
2
Value range 0–1
Presetting -
Example:
Tool ready status OK
Value 1