3 608 878 300 Tightening Technology | Bosch Rexroth AG 41/641
System 350 | 3 608 878 300/2019-03
Fig. 3–8: Interfaces of the integrated computer unit at the CS351 compact system
Depending on the compact system, the following interfaces are available:
XDN1 Motor breaker interface
X3U1, X3U2 Two USB host interfaces of the CS351 controller, compatible with specification 2.0
Slot A Slot for the use of type A standard modules
Slot A is without function in CC-CS351; inserted modules will not be detected.
Slot A is not available at CS351...-D NK.
Slot B1, B2 Two slots for the use of standard type B modules (serial, 24 V)
CS351E-G+ and CS351S-G+ do not feature slot B2 due to the integrated computer unit.
Reset Restart/reset button
X3C1 RS232 interface to CS351 controller
X7E1 Ethernet interface to CS351 controller
X6C1 Mass storage slot for CF350 (CF card)
XDVI DVI interface to connect an external monitor
X3U4 No function USB host interface for connection of an external pointing device
XDAC1, XDAC2 Interfaces for connection to the system bus 350
X6MSD2 Slot for a MicroSD memory card
X3C2 Connection of a printer or scanner to the computer unit
XDVI2 DVI interface to connect an external TFT monitor
X3U6, X3U7, X3U8 USB interfaces
X7E4, X7E5 Ethernet interfaces
St2
St1
X6MSD2
X3U6
X3U7
X3U8
X3C2
XDVI2
X7E4
X7E5