3 608 878 300 Tightening Technology | Bosch Rexroth AG 421/641
System 350 | 3 608 878 300/2019-03
MID 0512 Upload operation HVO button acknowledgement
MID 0513 Deactivation operation HVO button
MID 0515 Set HVO signal display
MID 0515 revision 001
Sent by: superordinate computer
The superior computer acknowledges actuation of an HVO button (upload actuation HVO button, MID 0511).
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response: none
Sent by: superordinate computer
The subscription to actuations of HVO buttons (Logon actuation HVO button, MID 0510) is reset.
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response MID Error no. Comment
Command accepted 0005 –
Command error 0004 89 Activation for operation HVO button not available
Sent by: superordinate computer
This message changes the display of the signal light on the HVO.
Note: -
Revision: Number Supported by
001 Rexroth OP and Rexroth OP-BMW
002 Rexroth OP-BMW (only used for internal function)
Data field: Parameter IDs and parameter values, 12 bytes
Possible response MID Error no. Comment
Upload operation HVO button
acknowledgement
0512 –
Table 6–118: MID 0515 revision 001
Parameter Comments Bytes
Signal 1 Defines the status of signal light 1 at the HVO.
ID 01
2
Value range – 0 (off)
–1 (on)
–2 (no change)
–3 (flashing)
Presetting -
Example:
Signal 1 Off
Value 0
1